Commands 2G Ericsson PDF
Commands 2G Ericsson PDF
To check cell status and call status/ To Check speech on time slot
(Cell down or not and call is processing or not )
To check/change HSN
rlcfp:cell=cell name;
rlchc:cell=cell name, CHGR=1, HSN=35; //CHANGE HSN OF a particular cell
To check/change POWER
RLCPP:CELL=CELL NAME; //Power check
RLCPC:CELL=CELLNAME,BSPWRB=?; //power change
PARAMETER CHANGE
TO change CGI in MSC
mgoce:cell=cellname; //DELETES CELL FROM MSC
mgoci:cell=cellname ,cgi=404-53-,MSC=MSC name; //CREATES CELL IN MSC
mgocp:cell=cellname; //Display cell list in MSC
To check/change HR
RLDHP:CELL=CELLNAME; //To check HR status on that particular cell
RLDHC:CELL=CELLNAME,DTHAMR=?; //To change HR status on that particular cell
To check/enable DTX
RLCXP:CELL=ALL; // To check DTX on or not(DL)
RLCXC:CELL=CELL NAME, DTXD=ON; //To change DTX status(DL)
PARAMETER CHANGE
To check/change ACCMIN and RLT
RLSSP:CELL=ALL; //To check ACCMIN,CCHPWR,CRH, UPLINK DTX, RLT
RLSSC:CELL=CELL NAME,ACCMIN/RLINKT etc=?; //To change ACCMIN,CCHPWR,CRH,
UPLINK DTX, RLT
To check BA list
RLMFP:CELL=CELLNAME;
TA LIMIT(CHECK/CHANGE) & MEDIA FLICK
MEDIA FLICK
RXAPP:MO=RXOTG-TGNO.;
RADEP:DEV=DEVNAME;
NTCOP:SNT=ETM2-V;
DTQDP:DIP=DIP NAME;
EXTERNAL CELL CREATION
RLDEI:CELL=XXX,EXT,CSYSTYPE= GSM900;
RLDEC:CELL=XXX,CGI=XXX,BSIC=XXX,BCCHNO=XXX;
RLCPC:CELL=XXX,MSTXPWR=33;
RLLOC:CELL=XXX,BSRXSUFF=150,MSRXSUFF=0,SCHO=OFF,AW=OFF,
MSRXMIN=100,BSRXMIN=121,BSPWR=55,EXTPEN=OFF,BSTXPWR=55,MISSNM=3;
RLLHC:CELL=XXX,LAYER=2,LAYERTHR=75,LAYERHYST=2,PSSTEMP=0,PTIMTEMP=
0;
// RUN ALL THE FIVE COMMANDS FOR EXTERNAL CELL CREATION BEFORE HANDOVER
DEFINITION
NOKIA OSS
ZEEI:BTS=XXX; //SEE CELL STATUS
ZEOL:BCFNO; //CHECK ALARMS
ZEEI:BCFNO; // SHOWS STSTUS FOR COMPLETE SITE
ZEQO:BTS=XXX:ALL; //SEE ALL PARAMETERS
ZEAC:BTS=XXX::ABTS=XXX; //DEFINE HO SAME BSC
ZEAC:BTS=XXX::MCC=404,MNC=55,LAC=XXX,CI=XXX:NCC=2,BCC=5,FREQ=XX
X; //DEFINE HO DIFF BSC
ZEAD:BTS=XXX::LAC=XXX,CI=XXX ; // DELETE CELL
THANK YOU